Skip to main content
  • Letter to the Editor
  • Open access
  • Published:

A patient with intraoperative awareness history requiring high propofol effect-site concentrations for general anesthesia

To the Editor,

Intraoperative awareness (IA) occurs in up to 0.12% of patients under general anesthesia [1]. Herein, we describe the case of patient with IA history requiring high propofol effect-site concentrations (PCe) for anesthesia. We obtained a written informed consent from the patient for publication. The patient was a 34-year-old woman (158 cm, 46 kg) who underwent a semi-emergency transcutaneous drainage of an intrapelvic tumor under computed tomography (CT) guidance. She was being administered celecoxib, loxoprofen, and pregabalin for chronic pain. She had undergone multiple operations for neurilemmomas, had experienced IA with unclear details, and desired a complete loss of consciousness for her upcoming operation. In the CT room, we induced anesthesia with fentanyl (150 μg) and propofol via target-controlled infusion (TCI, Diprifusor model, TE-371, Terumo, Tokyo, Japan). We initiated the target plasma concentration of propofol at 4 μg/mL and increased it gradually (Fig. 1). When the patient’s responses to voice, mild prodding, and shaking were lost, the PCe was 6.4 μg/mL and the patient state index (PSi) derived with SedLine® (Masimo, USA) was 79 (PSi 25–50 is recommended during anesthesia). At this stage, fast waves in electroencephalogram were still observed but were not predominant. Spectral edge frequency (SEF), which can be used as a surrogate measure to observe the change in the amount of fast waves, was 12.9 Hz. Following the tracheal intubation using rocuronium (40 mg), we moved the patient to a prone position and installed a mechanical ventilator. We titrated target propofol concentrations in accordance with PSi values and with the patient’s vital signs. The drainage was uneventfully completed. The maximum PCe was 8.0 μg/mL and the total fentanyl dose was 400 μg. Ten minutes after PCe reached 8.0 μg/mL, PSi and SEF were 22 and 10.8 Hz, respectively. The anesthesia duration was 100 min. The patient regained responsiveness to voice when the PCe decreased to 4.0 μg/mL. We did not observe any postoperative complications and the patient was satisfied with the clinical course without any IA. Although no consensus exists on IA, using inhalation anesthetics may produce less IA [2, 3]. However, the CT room was not equipped with the excess anesthesia gas extraction system and this prevented us from using inhaled anesthetics with an anesthesia machine, which is why we chose total intravenous anesthesia. Our patient required much higher PCes than usual (TCIs are 3.0–6.0 μg/mL and 2.0–5.0 μg/mL for anesthesia induction and maintenance, respectively; according to the propofol package insert; Diprivan®, Aspen Japan, Tokyo). The patient was apparently awake, although the probability of loss of response to prodding and shaking right before the patient lost responsiveness was predicted at 99.3% with the response surface model [4]. Therefore, we think she was relatively insensitive to propofol due to pharmacokinetic and/or pharmacodynamic variability, and this may have explained her previous IA. Although pregabalin reportedly reduces propofol requirements [5], our patient required a large propofol dose. Our case highlights the need to be aware of potential propofol insensitivities, especially in patients with IA history.

Fig. 1
figure 1

Time courses of propofol effect-site concentration (PCe, blue curve), fentanyl effect-site concentration (FCe, red curve), patient state index (PSi, gray curve), and probability of loss of response to prodding and shaking predicted with a response surface model (black curve) [4]. To use the model, (1) we converted PCes predicted with Diprifusor model to PCes predicted by Schinder model using the infusion record of propofol downloaded from the pump and (2) converted the FCes to remifentanil equivalents using a remifentanil:fentanyl equivalency ratio of 1:1.2. LOR, loss of responsiveness; ROR, return of responsiveness

Availability of data and materials

Not applicable

Abbreviations

CT:

Computed tomography

FCe:

Fentanyl effect-site concentration

IA:

Intraoperative awareness

PCe:

Propofol effect-site concentration

PSi:

Patient state index

TCI:

Target-controlled infusion

References

  1. Walker EMK, Bell M, Cook TM, Grocott MPW, Moonesinghe SR. Patient reported outcome of adult perioperative anaesthesia in the United Kingdom: a cross-sectional observational study. Br J Anaesth. 2016;117:758–66.

    Article  CAS  Google Scholar 

  2. Morimoto Y, Nogami Y, Harada K, Tsubokawa T, Masui K. Awareness during anesthesia: the results of a questionnaire survey in Japan. J Anesth. 2011;25:72–7.

    Article  Google Scholar 

  3. Domino KB, Posner KL, Caplan RA, Cheney FW. Awareness during anesthesia: a closed claims analysis. Anesthesiology. 1999;90:1053–61.

    Article  CAS  Google Scholar 

  4. Johnson KB, Syroid ND, Gupta DK, Manyam SC, Egan TD, Huntington J, White JL, Tyler D, Westenskow DR. An evaluation of remifentanil propofol response surfaces for loss of responsiveness, loss of response to surrogates of painful stimuli and laryngoscopy in patients undergoing elective surgery. Anesth Analg. 2008;106:471–9 table of contents.

    Article  CAS  Google Scholar 

  5. Chavush MA, Yagar S, Erturk A, Ozgok A. Preliminary investigation of preoperative pregabalin and total intravenous anesthesia doses: a randomized controlled trial. J Clin Anesth. 2017;41:137–40.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

None

Funding

The authors declare no funding for this report.

Author information

Authors and Affiliations

Authors

Contributions

SO treated the patient and wrote the manuscript. YN and RO treated the patient and revised the manuscript. TH treated the patient. CH and MM helped to design the case report. All authors reviewed and approved the final draft.

Corresponding author

Correspondence to Shinju Obara.

Ethics declarations

Ethics approval and consent to participate

In our institution, IRB approval is not required for a case report.

Consent for publication

Written informed consent was obtained from the patient for publication of this case report.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Obara, S., Noji, Y., Hasegawa, T. et al. A patient with intraoperative awareness history requiring high propofol effect-site concentrations for general anesthesia. JA Clin Rep 5, 71 (2019). https://doi.org/10.1186/s40981-019-0290-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40981-019-0290-6