Skip to main content

Table 1 Detailed mitral measurements and the planned ring sizes by the anesthesiologist

From: Transesophageal echocardiography in robot-assisted mitral valve repair for Barlow’s disease: usefulness for predicting artificial ring size and artificial chordae length using the loop technique

Cases

Intercommissural distance

A-height

Intertrigonal distance

Longitudinal diameter

Transverse diameter

Planned ring size

1

32.7

23.1

32.1

33.8

40.9

34

2

34.2

25.0

33.9

31.3

37.5

34

3

32.3

20.8

31.9

31.5

40.0

32

4

35.0

22.7

34.0

36.4

42.0

35

5

34.5

19.0

34.7

34.5

50.7

35

6

30.4

20.2

29.0

32.3

40.4

30

7

31.8

23.0

31.0

32.8

42.9

32

8

34.3

22.9

31.9

35.5

41.5

35

9

32.3

20.9

31.1

34.8

37.0

32

10

35.6

22.0

34.9

36.7

38.2

36

Median (IQR)

33.5 (32.3–34.5)

22.4 (20.8–23.0)

32.0 (31.3–34.0)

34.2 (31.3–32.4)

40.7 (38.7–41.9)

 
  1. Each case: mm
  2. Abbreviations: A-height the height of A2 segment of anterior leaflet