Skip to main content

Table 2 ROTEM findings

From: Rotational thromboelastometry-guided perioperative management of coagulation in a patient with Heyde’s syndrome undergoing transcatheter aortic valve implantation

  Before surgery 6 h after surgery 12 h after surgery 24 h after surgery 3 days after surgery
EXTEM
 CT (s) [38–79] 59 50 54 57 51
 CFT (s) [34–159] 200 130 123 131 103
 A10 (mm) [43–65] 35 44 44 44 49
 MCF (mm) [50–72] 44 52 52 53 56
INTEM
 CT (s) [100–240] 308 403 191 240 157
 CFT (s) [30–110] 190 182 123 127 102
 A10 (mm) [44–66] 38 37 43 44 47
 MCF (mm) [50–72] 47 46 51 51 52
FIBTEM
 A10 (mm) [7–23] 13 14 13 16
 MCF (mm) [9–25] 14 15 14 19
  1. Units are given in parentheses and reference ranges are given in square brackets
  2. ROTEM rotational thromboelastometry, EXTEM tissue factor reagent, INTEM contact coagulation activator reagent, FIBTEM modified EXTEM test with a platelet aggregation inhibitor, CT clotting time, CFT clot formation time, A10 amplitude at 10 min, MCF maximum clot firmness