Skip to main content

Table 2 Postoperative hemodynamic parameters and water balance

From: Implantation of ventricular assist device for systemic right ventricular failure in a patient with transposition of the great arteries and post-Mustard procedure: a case report

POD

0

1

2

3

4

5

6

7

8

9

10

CO (L/min)

4.8

5

5.3

5.1

5.2

5.1

5.5

    

PAP (mmHg)

30/17/23

38/24/29

43/27/34

42/22/31

52/33/41

51/34/40

45/25/33

    

CVP (mmHg)

10

12

12

12

13

13

13

14

12

13

11

Dial of Jarvik 2000*

3

3

3

3

3

2

3

3

3

3

3

Infusion volume (mL)

7984

3476

2937

2765

2806

3154

2968

2535

2758

2927

2928

Water output (mL)

3818

1297

1895

2055

2325

3245

2790

2760

2510

3940

2190

[Urine (mL)]

− 2864

− 787

− 1490

− 1815

− 2225

− 3195

− 2730

− 2660

− 2430

− 3870

− 2180

Water balance (mL)

4166

2179

1042

710

481

− 91

178

− 225

248

− 1013

738

Weight (kg)

60

62.1

62.6

63.5

63.7

64

62.5

62.9

62.2

60.6

59

Remarks

 

a

   

b

   

c

 
  1. POD postoperative day, CO cardiac output, PAP pulmonary artery pressure, CVP central venous pressure
  2. aWeaning from ventilator and dobutamine. bEmergence of pulmonary congestion and initiation of noninvasive positive-pressure ventilation and intensive diuretic therapy. cWeaning from noninvasive positive-pressure ventilation
  3. *The Jarvik 2000 pump speed and output were 10,000 rpm and 3–5 L/min on dial 3 and 9000 rpm and 2–4 L/min on dial 2